 LIFE-SAFETY PROTECTED PHYSICAL DESIGN MANUAL FOR VA FACILITIES

0 comments

file time: 2008-08-07

filetype:pdf

Click Here To Download...

Help - Help for Webmasters « back to results for "" Below is a cache of http://www.va.gov/facmgt/pubs/physical-security/dmphyseclsp_04.pdf. It's a snapshot of the page taken as our search engine crawled the Web.
The web site itself may have changed. You can check the current page or check for previous versions at the Internet Archive. Yahoo! is not affiliated with the authors of this page or responsible for its content. LIFE-SAFETY PROTECTED PHYSICAL DESIGN MANUAL FOR VA FACILITIES phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-1 FINAL DRAFT Security Door Openings (SDO) n MATRIx n TYPES n SCHEDULE The Security Door Opening (SDO) Matrix provides a summary of the primary
components and functional requirements for the various opening types found in
VA facilities. The Matrix is organized by facility type and entry type and is used in
conjunction with the Security Door Opening Schedule and the Security Door Types.
The Security Door Opening Schedule identifies specific hardware devices and
operational requirements for each opening type. The Security Door Types describes
the doors and the placement of hardware devices that may be installed on or near the
door to make the secured opening function properly. A FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-3 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
ACC
Outpatient Clinic
NHCU Public Entrance 101.A
101.B
101.C
101.D Exterior to Building Main Entrance Lobby with emergency egress Single, opaque, or framed glass
Single, laminated glass (frameless)
Pair, opaque, or framed glass
Pair, laminated glass (frameless) LSP New yes X Magnetic lock or electric strike yes LSP Existing yes X Magnetic lock or electric strike yes VBA
Where VA is the only tenant Public Entrance 101.A
101.B
101.C
101.D Exterior to Building Main Entrance Lobby with emergency egress Single, opaque, or framed glass
Single, laminated glass (frameless)
Pair, opaque, or framed glass
Pair, laminated glass (frameless) LSP New yes X Magnetic lock or electric strike yes LSP Existing yes X Magnetic lock or electric strike yes Hospital
ACC
Outpatient Clinic
NHCU Staff Entrance 103.A
103.B
103.C
103.D Exterior to Secondary Building Entrance with emergency egress Single, opaque, or framed glass
Single, laminated glass (frameless)
Pair, opaque, or framed glass
Pair, laminated glass (frameless) LSP New yes X Mag. lock, elec. strike, or F04 entry yes Alarmed exit LSP Existing yes X Mag. lock, elec. strike, or F04 entry yes Alarmed exit VBA
Where VA is the only tenant Staff Entrance 103.A
103.B
103.C
103.D Exterior to Secondary Building Entrance with emergency egress Single, opaque, or framed glass
Single, laminated glass (frameless)
Pair, opaque, or framed glass
Pair, laminated glass (frameless) LSP New no Push-button comb. or F04 entry yes Alarmed exit LSP Existing no Push-button comb. or F04 entry yes Alarmed exit Research
Facilities and Vivariums Staff Entrance 102.A
102.C Exterior to Secondary Building Entrance with emergency egress Single, opaque, or framed glass
Pair, opaque, or framed glass LSP New yes X Magnetic lock or electric strike yes Alarmed exit LSP Existing yes X Magnetic lock or electric strike yes Alarmed exit Hospital
ACC
Outpatient Clinic
NHCU
VBA Egress 104.A
104.C Exterior emergency egress only no access from exterior Single, opaque, or framed glass
Pair, opaque, or framed glass LSP New no Exit 01 yes Alarmed exit LSP Existing no Exit 01 yes Alarmed exit Hospital
ACC
Outpatient Clinic
NHCU
VBA Loading Dock 107.A
107.C Exterior from Loading Dock area to Building Interior -
pedestrian only Single opaque or framed glass
Pair opaque or framed glass LSP New no Push-button combination or F07 Storeroom yes Hold open alarm LSP Existing no Push-button combination or F07 Storeroom yes Hospital
ACC
Outpatient Clinic
NHCU
VBA Loading Dock 108.0 Exterior from Loading Dock area to Building Interior -
equipment and material deliveries Overhead coiling steel LSP New yes yes LSP Existing yes yes BUILDING EXTERIOR * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-4 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
ACC
Outpatient Clinic
NHCU Storage 109.A
109.C Exterior to Storage only with no entrance to building Single opaque
Pair opaque LSP New no F07 Storeroom or card reader yes LSP Existing no F07 Storeroom or card reader yes Hospital
ACC
Outpatient Clinic
NHCU
VBA Emergency Access 110.A Exterior to Building or Fire Control Center Single opaque or framed glass LSP New no Secure Key Storage F07 Storeroom no LSP Existing no Secure Key Storage F07 Storeroom no Hospital
ACC
Outpatient Clinic
NHCU
VBA Tunnel 111.A Exterior to Utility Tunnel Single opaque LSP New no F07 Storeroom yes IDS with alarm LSP Existing no F07 Storeroom yes IDS with alarm Child Care/
Development
Center Child Care 112.A
112.B
112.C
112.D Exterior to Main Entrance and exit Single, opaque, or framed glass
Single, laminated glass (frameless)
Pair, opaque, or framed glass
Pair, laminated glass (frameless) LSP New yes X Magnetic lock or electric strike yes LSP Existing no Push-button combination lock yes Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research and Vivarium Utility Connections 111.A
111.C Exterior to Commercial Power Connections Single, opaque
Pair, opaque LSP New no F07 Storeroom yes IDS with alarm LSP Existing no F07 Storeroom yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research and Vivarium Utility Connections 111.A
111.C Exterior to Telecommunications and Data Connections Single, opaque
Pair, opaque LSP New no F07 Storeroom yes IDS with alarm LSP Existing no F07 Storeroom yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research and Vivarium Utility Connections 113.A
113.C Exterior to Bulk Medical Gas Storage Single, opaque
Pair, opaque LSP New no F07 Storeroom no LSP Existing no F07 Storeroom no BUILDING EXTERIOR (continued) * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-5 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX BUILDING INTERIOR * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
ACC
Outpatient Clinic
NHCU General 201.A
201.B
201.C
201.D Public Lobby to Building Interior Single, opaque, or framed glass
Single, tempered glass (frameless)
Pair, opaque, or framed glass
Pair, tempered glass (frameless) LSP New no F04 Entry no LSP Existing no F04 Entry no VBA
Where VA is the only tenant General 201.A
201.B
201.C
201.D Public Lobby to Building Interior Single, opaque, or framed glass
Single, tempered glass (frameless)
Pair, opaque, or framed glass
Pair, tempered glass (frameless) LSP New no F04 Entry no LSP Existing no F04 Entry no Research Facilities and Vivariums General 202.A
202.C Public Lobby to Building Interior Single, opaque, or framed glass
Pair, opaque, or framed glass LSP New yes X Magnetic lock or electric strike yes LSP Existing yes X Magnetic, electric strike, or push-button combination yes Hospital
ACC
Outpatient Clinic
NHCU
VBA Mail Room 203.A
203.C Corridor to Mail Room Single, opaque, or framed glass
Pair, opaque, or framed glass LSP New yes X F07 Storeroom and electric strike yes LSP Existing no Push-button combination lock no Hospital
ACC
Outpatient Clinic
NHCU
VBA Security Control Center 204.A Corridor to SCC Single, opaque, or framed one-way glass LSP New yes X F07 Storeroom and electric strike yes FEBR (30 min./ Level III) LSP Existing no Push-button combination lock no FEBR (30 min./ Level III) Hospital
ACC
Outpatient Clinic Police Operations Unit 205.A Holding Area Single, opaque, or framed one-way glass LSP New yes X F07 Storeroom and electric strike yes LSP Existing yes X F07 Storeroom and electric strike yes Hospital
ACC
Outpatient Clinic
NHCU
VBA Guard Station 206.A Corridor to Security Guard Station Single, opaque, or framed glass LSP New yes F07 Storeroom and electric strike yes LSP Existing no Push-button combination lock no FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-6 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
NHCU Canteen Retail Store 207.A
207.B
207.C
207.D Corridor to Canteen Retail Store Single, opaque, or framed glass
Single, tempered glass (frameless)
Pair, opaque, or framed glass
Pair, tempered glass (frameless) LSP New no F07 Storeroom yes IDS with alarm LSP Existing no F07 Storeroom yes IDS with alarm Hospital
NHCU Canteen Storage 208.A
208.C Canteen Storage Room Single, opaque
Pair, opaque LSP New no F07 Storeroom yes IDS with alarm LSP Existing no F07 Storeroom yes IDS with alarm Hospital Agent Cashier 209.A Corridor to Agent Cashier Single, opaque, or framed glass LSP New yes X F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes X F07 Storeroom and electric strike yes IDS with alarm Hospital Credit Union 209.A Public Areas to Credit Union Single, opaque, or framed glass LSP New yes X F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes X F07 Storeroom and electric strike yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU Pharmacy Cache 210.A
210.C Corridor to Pharmacy Cache Single, opaque, or framed one-way glass
Pair, opaque, or framed one-way glass LSP New yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm 30 minute forced entry LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm 30 minute forced entry Hospital
ACC
Outpatient Clinic Pharmacy Dispensing 211.A Corridor to Pharmacy Dispensing Area Single, opaque, or framed one-way glass LSP New yes X F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes X F07 Storeroom and electric strike yes IDS with alarm Hospital
ACC
Outpatient Clinic Pharmacy Manufg 211.A Corridor to Pharmacy Manufacturing Area Single, opaque, or framed one-way glass LSP New yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm 30 minute forced entry LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm 30 minute forced entry Hospital
ACC
Outpatient Clinic Narcotics Vault 212.A Pharmacy Cache to Narcotics Vault Single, opaque, or wire mesh LSP New yes X PIN or Biometrics F07 Storeroom and electric strike yes Hold-open alarm LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike yes Hold-open alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA Veterans Records 213.A
213.C Corridor to Veterans Records Single, opaque, or framed glass
Pair, opaque, or framed glass LSP New yes X F07 Storeroom and electric strike yes IDS with alarm 15 minute forced entry LSP Existing no Push-button combination lock yes IDS with alarm 15 minute forced entry BUILDING INTERIOR (continued) * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-7 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
ACC
Outpatient Clinic
NHCU Medical Supplies 214.A
214.C Corridor to Medical Supply Storage Single, opaque
Pair, opaque LSP New no Push-button combination lock no LSP Existing no Push-button combination lock no Hospital
ACC
Outpatient Clinic
NHCU Linen Storage and Distrib. 215.A
215.C Corridor to Central Linen Storage and Distribution Single, opaque
Pair, opaque LSP New no Push-button combination lock yes IDS with alarm LSP Existing no Push-button combination lock yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Information Resource Mgmt. 216.A
216.C Corridor to Information Resource Management (IRM) Single, opaque or framed glass
Pair, opaque or framed glass LSP New yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Communications 217.A
217.C Corridor to Telephone Equipment Room Single, opaque or framed glass
Pair, opaque or framed glass LSP New yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Telephone and Data Closets 218.A
218.C Corridor to Telephone and Data Closets Single, opaque
Pair, opaque LSP New no F07 Storeroom no LSP Existing no F07 Storeroom no Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Electrical Closets 218.A
218.C Corridor to Electrical Closets Single, opaque
Pair, opaque LSP New no F07 Storeroom no LSP Existing no F07 Storeroom no BUILDING INTERIOR (continued) * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-8 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
ACC
Outpatient Clinic
NHCU
Research Facilities Medical Media Equipment Storage 219.A
219.C Corridor to Medical Media Equipment Storage Single, opaque or framed glass
Pair, opaque or framed glass LSP New yes F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes F07 Storeroom and electric strike yes IDS with alarm Hospital
ACC
Outpatient Clinic Evidence Storage 220.A Corridor to Evidence Storage Single, opaque LSP New yes X F07 Storeroom and electric strike yes IDS with alarm FEBR (15 min./ Level III) LSP Existing yes X F07 Storeroom and electric strike yes IDS with alarm FEBR (15 min./ Level III) Hospital
ACC
Outpatient Clinic Weapon Storage/ Armory 221.A Security Control Center to Weapon Storage/Armory Single, opaque LSP New yes X PIN or Biometrics F07 Storeroom, electric strike, and magnetic lock yes IDS with alarm FEBR (15 min./ Level III) LSP Existing yes X PIN or Biometrics F07 Storeroom, electric strike, and magnetic lock yes IDS with alarm FEBR (15 min./ Level III) Hospital
Research Facilities Animal Research Facility 222.A
222.C Public Area to Animal Research Facility or Vivarium Single, opaque or framed glass
Pair, opaque or framed glass LSP New yes X PIN or Biometrics F07 Storeroom and electric strike, or magnetic lock yes IDS with alarm LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike, or magnetic lock yes IDS with alarm Hospital
Research Facilities Research and Clinical Labs 222.A
222.C Public Areas to Research and Clinical Laboratories Single, opaque or framed glass
Pair, opaque or framed glass LSP New yes X PIN or Biometrics F07 Storeroom and electric strike, or magnetic lock yes IDS with alarm LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike, or magnetic lock yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
Research Facilities Radio- active Materials Storage 223.A
223.C Corridor to Areas Containing Radioactive Materials Single, opaque
Pair, opaque LSP New yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm LSP Existing yes X PIN or Biometrics F07 Storeroom and electric strike yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Fire Control Center 224.A Fire Control Center to Building Interior Single, opaque LSP New no F07 Storeroom yes IDS with alarm LSP Existing no F07 Storeroom yes IDS with alarm BUILDING INTERIOR (continued) * References for ANSI/BHMA Designations: F-__ ANSI/BHMA ; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-9 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Hospital
Research Facilities Restricted Access Floors 225.0 Elevator to Restricted or Controlled Floor Opaque elevator cab and entrance doors LSP New yes X Elevator Door Control yes LSP Existing yes X Elevator Door Control yes Hospital
Research Facilities Restricted Access Floors 226.A Stair to Restricted or Controlled Area Single, opaque LSP New yes X Electric Strike and Exit 13 yes LSP Existing yes X Electric Strike and Exit 13 yes Hospital
Research Facilities Restricted Access Floors 227.A
227.C Corridor to Restricted or Controlled Area Single, opaque Pair, opaque LSP New yes X F07 Storeroom and electric strike yes LSP Existing yes X F07 Storeroom and electric strike yes Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Elevator Equipment Room 228.A
228.C Corridor to Elevator Equipment Room Single, opaque Pair, opaque LSP New yes X F07 Storeroom and electric strike yes LSP Existing no Push-button combination lock yes IDS with alarm Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Building Systems 228.A
228.C Corridor to Building Systems Rooms Single, opaque Pair, opaque LSP New yes X F07 Storeroom and electric strike yes LSP Existing no Push-button combination lock no Hospital
ACC
Outpatient Clinic
NHCU
VBA
Research Facilities Mech. and Electrical 228.A
228.C Corridor to Mechanical and Electrical Rooms Single, opaque Pair, opaque LSP New yes X F07 Storeroom and electric strike yes LSP Existing no Push-button combination lock no Hospital
Research Facilities Select Agents 229.A
229.C Rooms with Select Agents Single, opaque or framed glass Pair, opaque or framed glass LSP New yes X F07 Storeroom and electric strike yes LSP Existing yes X F07 Storeroom and electric strike yes Hospital
Research Facilities BSL Labs 230.A
230.C Public Areas to BSL-3 Laboratory Suites Single, opaque or framed glass Pair, opaque or framed glass LSP New yes X PIN or Biometrics Magnetic Lock or electric strike yes LSP Existing yes X PIN or Biometrics Magnetic Lock or electric strike yes BUILDING INTERIOR (continued) * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-10 a p p e N D I X a SECURITY DOOR OPENINGS MATRIX Facility Type Entry Type SDO Locations and Descriptions Facility Classification Access Control Monitoring Other Card Reader Fail Safe Fail Secure Other ANSI/BHMA* or other function Door Contact Other Research Facilities Vivariums 222.A
222.C Public Area to Vivarium Single, opaque or framed glass Pair, opaque or framed glass LSP New yes X PIN or Biometrics Magnetic Lock or electric strike yes LSP Existing yes X PIN or Biometrics Magnetic Lock or electric strike yes Research Facilities Vivariums 222.A
222.C Vivarium Exit Single, opaque or framed glass Pair, opaque or framed glass LSP New yes X EXIT 01 yes LSP Existing yes X EXIT 01 yes Hospital
NHCU Psychiatric Units 231.A Public Areas to Psychiatric Unit Single, framed glass LSP New yes X F01 Passage and magnetic lock yes Monitor at NS LSP Existing yes X F01 Passage and magnetic lock yes Monitor at NS Hospital
NHCU Psychiatric Units 232.A Psychiatric Unit Exit Only Single, framed glass LSP New no F01 Passage and magnetic lock yes Monitor at NS LSP Existing no F01 Passage and magnetic lock yes Monitor at NS Hospital COOP 233.A
233.C Public Areas to COOP Single, opaque
Pair, opaque LSP New yes X F07 Storeroom, electric strike, and magnetic lock yes PIN or Biometrics LSP Existing yes X F07 Storeroom, electric strike, and magnetic lock yes PIN or Biometrics BUILDING INTERIOR (continued) * References for ANSI/BHMA Designations: F-__ ANSI/BHMA A156.13; Exit __ ANSI/BHMA A156.3 FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-11 a p p e N D I X a SECURITY DOOR OPENINGS TYPES VA Standard Security Door Types A and C FINAL DRAFT C h a p t e r 2 SECURITY DOOR OPENINGS TYPES A-12 DepartMeNt OF VeteraNS aFFaIrS a p p e N D I X a VA Standard Security Door Types B and D FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-13 a p p e N D I X a SECURITY DOOR OPENING SCHEDULE Security Door Opening General Notes and Schedule 1. The hardware devices identified below indicate those generally required to meet the operational and security requirements. They are not all inclusive. Certain devices
may not be applicable to every opening. For example, flush bolts are not required
for single doors and neither continuous hinges nor electric strikes would be used on
frameless doors. 2. When optional operational features are provided, refer to Security Door Openings Matrix for requirements by facility classification. 3. Items required for functional purposes that are not related to door operation are not included in the descriptions below. For example, an intercom may be required at a
guard booth so that a visitor can communicate with the guard, but it is not required for
door operation. SDO 101 Hardware Devices: n Card Reader n Closer n Continuous Hinge or Pivots n Door Contact n Electric Strike n Exit Device n Flush Bolts n Intercom n Magnetic Lock n Mortise Lock Normal Daytime Operation n Free operation from either side After Hours Operation n Exterior lever inoperative n Card reader on exterior releases electric strike or magnetic lock n Remote release releases electric strike or magnetic lock n Free operation from interior n Door contact alarmed to central monitoring FINAL DRAFT C h a p t e r 2 SECURITY DOOR OPENINGS SCHEDULE A-14 DepartMeNt OF VeteraNS aFFaIrS a p p e N D I X a SDO 102 Hardware Devices n Card Reader n Closer n Continuous Hinge n Door Contact n Electric Strike n Exit Device n Flush Bolts n Hold-open Alarm n Intercom n Magnetic Lock n Mortise Lock Operation At All Times n Outside lever always rigid n Card reader releases electric strike n Free operation from interior at all times SDO 103 Hardware Devices n Card Reader n Closer n Continuous Hinge or Pivots n Deadbolt n Door Contact n Electric Strike n Exit Device n Flush Bolts n Hold-open Alarm n Magnetic Lock n Mortise Lock n Pull Normal Daytime Operation n Free operation from either side After Hours Operation n Exterior lever inoperative n Card reader on exterior releases electric strike or magnetic lock n Delayed action and alarmed operation from interior when door is a means of egress; card reader for egress when door is not a required means of egress n Door contact alarmed to central monitoring FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-15 a p p e N D I X a SECURITY DOOR OPENING SCHEDULE SDO 104 Hardware Devices n Closer n Continuous Hinge or Pivots n Door Contact n Exit Device n Flush Bolts n Hold-open Alarm n Mortise Lock Operation At All Times n Operation of exit device from inside retracts bolt and sounds local alarm and central monitoring station n No operation from exterior SDO 105 Hardware Devices n Power Operator n Card Reader n Continuous Hinge n Intercom n Magnetic Lock Normal Daytime Operation n Power operated doors (swinging or horizontal sliding) n Door activated by motion sensor on interior and exterior After Hours Operation n Power operated doors (swinging or horizontal sliding) n Door activated from exterior by card reader or remote release n Door activated by motion sensor on interior FINAL DRAFT C h a p t e r 2 SECURITY DOOR OPENINGS SCHEDULE A-16 DepartMeNt OF VeteraNS aFFaIrS a p p e N D I X a SDO 106 Hardware Devices n Card Reader n Closer n Continuous Hinge or Pivots n Door Contact n Electric Strike n Exit Device n Flush Bolts n Intercom n Magnetic Lock n Mortise Lock Normal Daytime Operation n Free operation at all times After Hours Operation n Exterior lever inoperative n Card reader on exterior releases electric strike or magnetic lock n Remote release releases electric strike or magnetic lock n Free operation from interior n Door contact alarmed to nurses station SDO 107 Hardware Devices n Card Reader n Closer n Continuous Hinge n Door Contact n Electric Strike n Flush Bolts n Hold-open Alarm n Mortise Lock Operation At All Times n Outside levers always rigid n Card reader releases electric strike or key in outside lever retracts latchbolt n Inside lever retracts latchbolt at all times n Hold-open alarm annunciates at central monitoring station FINAL DRAFT C h a p t e r 1 phYSICaL SeCUrItY DeSIGN MaNUaL: LIFE-SAFETY PROTECTED FACILITIES A-17 a p p e N D I X a SECURITY DOOR OPENING SCHEDULE SDO 108 Hardware Devices n Card Reader n Door Contact n Intercom Operation At All Times n Card reader activates motorized door operator or provides access to manual operator SDO 109 Hardware Devices n Continuous Hinge n Door Contact n Flush Bolts Operation At All Times n Outside lever always rigid n Inside lever retracts latchbolt at all times n Door contact alarmed to central monitoring station SDO 110 Hardware Devices n Closer n Continuous Hinge n Knox Box